SERVICE PROGRAM MODE 20 September 1999
A265/A267 4-80 SM
4.2.17 ID SENSOR ERROR ANALYSIS (SP2-221)
Even if the ID sensor is defective, the machine does not generate an SC condition.
If the ID sensor is defective, the image quality becomes worse (e.g., dirty
background on the copy). If these conditions occur, check the ID sensor output
using this SP mode.
1. Vsg
Error Condition: Vsg < 2.5V
Possible causes:
ID sensor defective
ID sensor dirty
Drum does not get charged
2. Vsp
Error Condition: Vsp > 2.5V
Possible causes:
Toner density is very low
ID sensor pattern is not created
3. Power: This is the power for the light source in the ID sensor
Error Condition: Vsg < 3.5V when maximum power (254) is applied
Possible causes:
ID sensor defective
ID sensor dirty
Drum does not get charged
4. Vsg-Vsp
Error Condition: (Vsg – Vsp) < 1.00V
Possible causes:
ID sensor defective
Drum dirty
5. Vt
Error Condition: Vt > 4.5V or Vt < 0.5V
Possible causes:
TD sensor defective
Vsg: 4.01V Vsp: 1.09 Power: 65
Vsg-Vsp: 2.98V Vt: 2.3V