FUSING/EXIT
SM 6-21 A265/A267
Replacement
Adjustment
6.5.6 PAPER EXIT SENSOR/PAPER OVERFLOW SENSOR
1. Remove the front upper cover [A] (1 screw, 1 hook).
2. Remove the exit cover [B].
NOTE:
If the optional 1 bin tray unit and/or interchange unit have been
installed, remove them.
3. Replace the exit sensor [C] (1 connector).
4. Replace the overflow sensor [D] (1 connector).
A267R601.WMF
[A]
[B]
[C]
[D]