BIT SWITCHES
A256/A257 2-2 SM
2.2 BIT SWITCHES
&
WARNING
Do not adjust a bit switch or use a setting that is described as "Not used",
as this may cause the machine to malfunction or to operate in a manner
that is not accepted by local regulations. Such bits are for use only in other
areas, such as Japan.
NOTE:
After changing any of the switches below, turn off the machine, wait for 5
seconds or more, and turn it back on, so that the new settings take effect.
2.2.1 G4 INTERNAL SWITCHES
Bit Switch 00
No. FUNCTION COMMENTS
0
to
7
Country code
Bit43210Country
00000France
00001Germany (1TR6 mode)
00010Universal (Europe Euro ISDN)
10001USA
Note:
In Germany, use the UK setting for the Euro ISDN lines.
Bit switches 01 and 02 are not used.
Bit Switch 03
No. FUNCTION COMMENTS
0
Amount of protocol dump
data in one protocol dump
list
0:
Last communication only
1:
Up to the limit of the
memory area for protocol
dumping
Change this bit to 0 if you want to have a protocol
dump list of the last communication only.
This bit is only effective for the dump list #2 (D +
Bch1).
1-7
Not used Do not change the factory settings.