SERVICE PROGRAM MODE
A265/A267 4-6 SM
Mode No.
Class
1 and 2
Class
3
Function Settings
2
Paper Feed Timing
(2nd, 3rd, 4th Paper
Feed, LCT, and By-
pass Feed)
0 ~ 10
1 mm/step
5 mm
1-003*
3
Paper Feed Timing
(Duplex)
Adjusts the paper feed clutch timing at
registration. The paper feed clutch timing
determines the amount of paper buckle at
registration. (A larger setting leads to more
buckling.)
0 ~ 20
1 mm/step
6 mm
1-007
By-pass Paper Size
Display
Displays the by-pass paper width sensor
output.
1
Fusing Temperature
Adjustment
(Stand-by)
Adjusts the fusing temperature for standby
mode.
155 ~ 190
1°C/step
170°C
Adjusts the fusing temperature for low
power level 2.
2
Fusing Temperature
Adjustment
(Low Power
Level 2)
With a lower value, the machine takes more
time to reach the ready condition.
0 ~ 80
1°C/step
80°C
1-105*
3
Fusing Temperature
Adjustment
(Special Paper)
Adjusts the additional fusing temperature for
the special paper mode selected by the
lever on the 2nd paper tray; also for the
bypass tray (all paper types).
0 ~ 20
1°C/step
10°C
Displays the fusing temperature.
1-106
Fusing Temp.
Display
Press the
"
(Clear Modes) key to exit the
display.
Adjusts the number of zero-cross cycles of
the fusing lamp ac supply needed for the
fusing lamp power to reach 100%. Use a
higher number if the customer complains
about sudden power dropouts.
For European models, this SP mode is
effective in the stand-by mode and
energy saver mode only.
1
Fusing Soft Start
Adjustment
(Stand-by, Energy
saver)
See “Detailed Descriptions - Fusing Unit” for
details on SP1-107, Section 2.10.6.
N. America
0: 3 times
1: 10 times
2: 20 times
Europe/Asia
0: 5 times
1: 10 times
2: 20 times
For European models only.
Adjusts the number of zero-cross cycles of
the fusing lamp ac supply needed for the
fusing lamp power to reach 100% when
raising the temperature during printing. Use
a higher number if the customer complains
about sudden power dropouts.
1-107*
2
Fusing Soft Start
Adjustment
(Printing)
See “Detailed Descriptions - Fusing Unit” for
details on SP1-107, Section 2.10.6.
0: 5 times
1: 10 times
2: 20 times
Selects whether the fusing temperature
control cycle is 1 or 3 seconds.
For European models, this SP mode is
effective in the stand-by mode and
energy saver mode only.
1-108* 1
Fusing Soft Start
Setting
(Stand-by, Energy
saver)
If this is “1”, the power supply fluctuates less
when the fusing lamp turns on. See
“Detailed Descriptions - Fusing Unit” for
details, Section 2.10.6.
0: 1 sec
1: 3 sec

Table of Contents