EasyManua.ls Logo

Ricoh Aficio 270 - Page 213

Ricoh Aficio 270
860 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE PROGRAM MODE
SM 4-27 A265/A267
Service
Tables
Mode No.
Class
1 and 2
Class
3
Function Settings
Checks the difference value of the black
level for the ODD channel after adjusting the
black level at power-up.
2*
SBU Gain
Adjustment
(ODD)
Do not change the value.
However, after doing a memory all clear
(SP5-801), use it to re-input the previous
value.
0 ~ 255
1/step
40
Checks the difference value of the black
level for the EVEN channel after adjusting
the black level at SBU Auto Adjustment
(SP4-908).
3
SBU Gain
Adjustment
(Adjusted EVEN)
Do not change the value.
0 ~ 255
1/step
40
Checks the difference value of the black
level for the ODD channel after adjusting the
black level at SBU Auto Adjustment (SP4-
908).
4-904
4
SBU Gain
Adjustment
(Adjusted ODD)
Do not change the value.
0 ~ 255
1/step
40
Adjusts the coefficient of the D/A converter
for the AGC gain curve for DC cont for the
EVEN channel.
1
SBU DC Cont
Adjustment
(EVEN)
Do not change the value.
However, after doing a memory all clear
(SP5-801), use it to re-input the previous
value.
0 ~ 255
1/step
25
Adjusts the coefficient of the D/A converter
for the AGC gain curve for DC cont for the
ODD channel.
4-905*
2
SBU DC Cont
Adjustment (ODD)
Do not change the value.
However, after doing a memory all clear
(SP5-801), use it to re-input the previous
value.
0 ~ 255
1/step
25
Adjusts the coefficient of the D/A converter
for the AGC gain curve for scanning the
white plate.
1
SBU Ref. Value
Adjustment
(Current Value)
Do not change the value.
0 ~ 255
1/step
147
Displays the number of convergences for
SBU reference control.
4-906
2
SBU Ref. Value
Adjustment (Loop)
Do not use in the field.
0 ~ 255
1/step
0
Adjusts the coefficient of the D/A converter
for the offset (Z/C) for the analog image data
processing for EVEN.
4-907* 1
SBU Offset Value
Adjustment (EVEN)
Do not change the value.
However, after performing the memory all
clear (SP5-801), use it to re-input the
previous value.
0 ~ 255
1/step
180
Adjusts the coefficient of the D/A converter
for the offset (Z/C) for the analog image data
processing for ODD.
4-907* 2
SBU Offset Value
Adjustment (ODD)
Do not change the value.
However, after performing the memory all
clear (SP5-801), use it to re-input the
previous value.
0 ~ 255
1/step
180

Table of Contents

Other manuals for Ricoh Aficio 270

Related product manuals