SERVICE PROGRAM MODE
A265/A267 4-30 SM
Mode No.
Class
1 and 2
Class
3
Function Settings
23
P - MTF Coefficient
(Text /Binary /Main
/25%~49%)
0 ~ 15
1/step
1
24
P - MTF Coefficient
(Text /Binary /Main
/50%~95%)
0 ~ 15
1/step
1
25
P - MTF Coefficient
(Text /Binary /Main
/96%~125%)
0 ~ 15
1/step
1
26
P - MTF Coefficient
(Text /Binary /Main
/126%~159%)
0 ~ 15
1/step
3
27
P - MTF Coefficient
(Text /Binary /Main
/160%~200%)
0 ~ 15
1/step
4
28
P - MTF Coefficient
(Text /Binary /Main
/201%~)
0 ~ 15
1/step
4
29
P - MTF Coefficient
(Text /Binary /Sub
/25%~49%)
0 ~ 15
1/step
2
30
P - MTF Coefficient
(Text /Binary /Sub
/50%~95%)
0 ~ 15
1/step
2
31
P - MTF Coefficient
(Text /Binary /Sub
/96%~125%)
0 ~ 15
1/step
2
32
P - MTF Coefficient
(Text /Binary /Sub
/126%~159%)
0 ~ 15
1/step
3
33
P - MTF Coefficient
(Text /Binary /Sub
/160%~200%)
0 ~ 15
1/step
4
34
P - MTF Coefficient
(Text /Binary /Sub
/201%~)
0 ~ 15
1/step
4
35
P - MTF Coefficient
(T/P /Binary /Main
/25%~49%)
0 ~ 15
1/step
3
36
P - MTF Coefficient
(T/P /Binary /Main
/50%~89%)
0 ~ 15
1/step
3
37
P - MTF Coefficient
(T/P /Binary /Main
/90%~95%)
0 ~ 15
1/step
3
4-915*
38
P - MTF Coefficient
(T/P /Binary /Main
/96%~125%)
This adjustment is only effective for the
“Service Mode” original type setting.
Selects the MTF filter coefficient in the
binary picture processing mode. See
“Detailed Descriptions - Image Processing”
for details.
T/P: Text/Photo, Section 2.2.4.
0 ~ 15
1/step
1