ROM HISTORY
SM 4-85 A265/A267
Service
Tables
A265/A267 Firmware Modification History (BICU)
Description of Modification Firmware Level Serial Number
Firmware
Version
•
On machines with an optional
LCT installed, SC507 can occur
when the main power SW is
turned on under the following
conditions: 1. The LCT end
fence is not in the HP
and
2.
The bottom plate for the right
tray is not detected by the lower
HP sensor.
However, these occurrence
conditions are very rare.
•
“1/2” appears in the Key
Operator Tools display (inside
user tools – system settings).
•
After the operator exits either of
the following screens with the
User Tools key and starts a
copy job, the first sheet is
printed out as the counter list.
!
System Settings – Key Operator
Tools – Counter List Printing
!
Copy Features– Key Operator
Tools – Counter List Printing
Corrects the following:
•
In printer mode, dirty back-
ground may appear near the
leading edge of the first page
printed out following a paper
jam recovery.
•
When exiting to the 1-bin tray,
a paper jam may occur caused
by the bouncing of the exit
sensor actuator.
A2675532 D March 2000
production.
1.74
Rev. 04/2000