Trouble-
shooting
SERVICE CALL CONDITIONS
SM 7-5 A265/A267
SC322: Laser synchronization error
-Definition- [B]
The main scan synchronization detector board cannot detect the laser
synchronization signal for more than 5 consecutive 100 ms intervals.
- Possible causes -
Poor connection between the laser synchronization detector board and the
BICU board
Laser synchronization detector board out of position
Laser synchronization detector board defective
BICU board defective
LD unit defective
SC324: LD drive current over
-Definition- [B]
The LD drive board applies more than 100 mA to the LD.
- Possible causes -
LD unit defective (not enough power, due to aging)
Poor connection between the LD unit and the BICU board
BICU board defective
SC390: TD sensor error
-Definition- [B]
The TD sensor outputs less than 0.5V or more than 4.0V 10 times consecutively
during copying.
- Possible causes -
TD sensor abnormal
Poor connection of the PCU
SC391: Development bias leak
-Definition- [B]
A development bias leak signal is detected.
- Possible causes -
Poor connection of the PCU
High voltage supply board defective