BIT SWITCHES
SM 4-43 A265/A267
Service
Tables
A895
Communication Switch 02
No FUNCTION COMMENTS
2 Treatment of pages received
with errors during G3
reception
0: Deleted from memory
without printing
1: Printed
0: Pages received with errors are not printed.
3 Hang-up decision when a
negative code (RTN or PIN) is
received during G3 immediate
transmission
0: No hang-up, 1: Hang-up
0: The next page will be sent even if RTN or PIN
is received.
1: The machine will send DCN and hang up if it
receives RTN or PIN.
This bit is ignored for memory transmissions or if
ECM is being used.
4-6
Not used Do not change the settings.
7
Method of total error rate
calculation
0: Normal method
1: French PTT requirement
0: Error rate is calculated by dividing the number
of total lines by the number of error lines.
1: Error rate is calculated by dividing the number
of total plus error lines by the number of error
lines.
Communication Switch 03
No FUNCTION COMMENTS
0
to
7
Maximum number of page
retransmissions in a G3
memory transmission
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)