BIT SWITCHES
A265/A267 4-66 SM
SG3 Switch 0B
No FUNCTION COMMENTS
0 Protocol requirements:
Europe
0: Disabled 1: Enabled
1
Protocol requirements: Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3 Protocol requirements: France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5
PTT requirements: France
0: Disabled 1: Enabled
The machine does not automatically reset these
bits for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
6
Not used Do not change the setting.
7
Not used Do not change the setting.
SG3 Switch 0C
No FUNCTION COMMENTS
0
1
Pulse dialing method
Bit 1 Bit 0 Setting
0 0 Normal(P=N)
0 1 Oslo (P=10 - N)
1 0 Sweden
(N+1)
1 1 Not used
P = Number of pulses sent out, N = Number
dialed.
2-7
Not used Do not change the settings.
SG3 Switch 0D - Not used (do not change the settings)
SG3 Switch 0E - Not used (do not change the settings)
SG3 Switch 0F - Not used (do not change the settings)