SERVICE RAM ADDRESSES
SM 4-91 A265/A267
Service
Tables
A895
6800D8(H) - User parameter switch 24 (SWUSR_18)
Bits 0 and 1: File retention time (Cross reference: System switch 02 bit 4)
Bit 1 0 Setting
0 0 File retention impossible
0 1 24 hours
1 0 File retention impossible
1 1 72 hours
Bits 2 to 7: Not used
6800D9(H) - User parameter switch 25 (SWUSR_19)
Bits 0 to 3: Not used
Bit 4: RDS operation
0: Not acceptable
1: Acceptable for the limit specified by system switch 03
Note:
This bit is only effective when RDS operation can be selected by the user
(see system switch 02).
Bits 5 and 6: Not used
Bit 7: Daylight saving time 0: Disabled, 1: Enabled
6800DA(H) - User parameter switch 26 (SWUSR_1A)
(This switch is not printed on the user parameter list.)
Bit 0: Not used
Bit 1: PSTN-1 Dialing type 0: Pulse dialing (10 pps), 1: Tone (DTMF) dialing
Bits 2 to 4: Not used
Bits 5: PSTN-2 Dialing type 0: Pulse dialing (10 pps), 1: Tone (DTMF) dialing
6800DB(H) - User parameter switch 27 (SWUSR_1B)
PSTN-1 access code from behind a PABX
(This switch is not printed on the user parameter list.)
Access number Hex value to program (BCD)
0 F0
0 F0
00 00
99 99
6800DC(H) to 6800DF - User parameter switch 28 to 31 (SWUSR_1C to 1F)
Bits 0 to 7: Not used
6800E0 to 6800EF(H)
- G4 Parameter Switches
(Refer to the ISDN G4 option service manual for details.)
6800F0 to 68010F(H)
- G4 Internal Switches
(Refer to the ISDN G4 option service manual for details.)
680110 to 68011E(H)
- Service station’s fax number (Service mode 09)
See 68027C(H) for the type of network used for this number
.