Printer
Controller
B306
SC CODES
SM 6-1 A265/A267
6. TROUBLESHOOTING
6.1 SC CODES
SC No. Description Required Action
2001 Power-on Self-Diagnostics Error Check the error code using [Service
Menu] – [Diag. Error].
2002 FGATE error Check any SC errors for the engine.
6.2 ERROR CODES
Code Description Required Action
0201 On-board SDRAM read/verify
failed.
Replace the controller if this error is
frequent.
0301
SDRAM DIMM (option)
read/verify failed.
Replace the SDRAM DIMM if this error
is frequent.
0Fxx Controller – BiCU interface error. Check the connectors and cable
connections.
Replace the motherboard, cable, and/or
BiCU.
1101 Data transmission did not finish
within the specified time.
An incompatible loop-back connector is
connected to the parallel port, or the
loop-back connector is not connected.
Use the correct loop-back connector
(P/#: G0219350) before the test.
1102 Data looped back to the controller
is not the same as the data
transmitted.
The loop-back connector may be
defective. Try using another one.
11xx Centronics parallel interface error. Replace the controller if this error is
frequent.
1401 The controller NVRAM has a
problem.
1402
NVRAM checksum error or the
battery has run out.
1403 NVRAM write error
1404 NVRAM read error
Replace the NVRAM if this error is
frequent.
1501 RTC error
Replace the controller if this error is
frequent.
1601 Font ROM error Replace the controller if this error is
frequent.
1602 The data in the Font ROM is
damaged.
Replace the controller if this error is
frequent.
1Bxx Option bus A (CN506) error
Check the connection to the optional
component at CN506.
Try replacing the optional NIB or HDD.