SERVICE PROGRAM MODE
A265/A267 4-44 SM
Mode No.
Class
1 and 2
Class
3
Function Settings
Specifies whether the counter is doubled for
A3/11" x 17" paper.
5-104*
A3/DLT Double
Count
If “Yes” is selected, the total counter
(mechanical counter) and the current user
code counter counts up twice when A3/11" x
17" paper is used.
0: No
1: Yes
5-106*
ADS Level Selection Selects the image density level that is used
in ADS mode.
1 ~ 7
1 notch/step
4
Selects the optional counter type.
5-113*
Option Counter Type
After installing the optional key counter, this
SP must be set to “1”.
0: None
1: Key
Counter
5-116*
Key Counter Up
Timing
Determines whether the total counter counts
up at paper feed-in or at paper exit.
0: Feed In
1: Exit
5-120*
Opt. Counter Reset
Setting
This SP is for Japan only. Do not change
the value.
0: Yes
1: Stand-by
2: None
DF 180
°
Image
Rotation
Select whether the image is rotated 180
°
(upside down) in DF mode.
0: No
1: Yes
5-143
Selects “Yes” when making a copy on a
letter headed page when feeding from a
paper tray.
User Code Mode
(Copier)
Selects whether the user code feature is
enabled in copy mode or not.
0: No
1: Yes
1
If this value is changed, the user tool setting
is also changed.
User Code Mode
(Fax)
This SP is for Japan only. Do not change
the value.
0: No
1: Yes
2
If this value is changed, the user tool setting
is also changed.
User Code Mode
(Printer)
This SP is for Japan only. Do not change
the value.
0: No
1: Yes
5-401*
3
If this value is changed, the user tool setting
is also changed.
Sets the PM interval.
1
PM Alarm Interval
The value stored in this SP is used when the
value of SP5-501-2 and/or -3 is “1”.
1 ~ 255
1k copies
/step
120k
copies
Selects whether the PM alarm for the
number of prints/copies is enabled or not
2
PM Alarm Mode
(Prints)
If this is “1”, the PM alarm function is
enabled.
0: No
1: Yes
This SP is for Japan only. Do not change
the value.
Selects whether the PM alarm for the
number of scans is enabled or not
5-501*
3
PM Alarm Mode
(Original)
If this is “1”, the PM alarm function is
enabled.
0: No
1: Yes
⇒
Rev. 03/2000