FUSING/PAPER EXIT 10 February 2005
3-40
6. Paper exit tray [A] ( x 2)
7. Paper exit lower cover [B] ( x 1)
8. Paper exit unit [C] ( x 3, x 1)
NOTE: Remove 2 connectors
before removing the unit. To
remove the last connector,
remove the unit and turn it
over. The connector is on
the bottom.
9. Paper exit sensor [D]
10. Paper overflow sensor [E]
B156R274.WMF
B156R275.WMF
[E]
[C]
[D]
[B]
[A]