R&S ESCI Receiver – Operation on a Discrete Frequency
1166.6004.12 4.5 E-2
Table 4-2 ANALYZER SETUP of R&S ESCI
Parameter Settings
Mode Spectrum
Center frequency step size 0.1 * center frequency
RF attenuation auto (10 dB)
Reference level -20 dBm
Level range 100 dB log
Level unit dBm
Sweep time auto
Resolution bandwidth auto (3 MHz)
Video bandwidth auto (10 MHz)
FFT filters off
Span / RBW 50
RBW / VBW 0.33
Sweep cont
Trigger free run
Trace 1 clr write
Trace 2/3 blank
Detector auto peak
Trace math off
Frequency offset 0 Hz
Reference level offset 0 dB
Reference level position 100 %
Grid abs
Cal correction on
Noise source off
Input RF
Display Full screen, active screen A
Tracking generator (only with option R&S FSP-B9) off
External generator 1/2 (only with option R&S FSP-B10) off
Preamplifier off
Preselector off

Table of Contents