MRD 3187B - User Manual
Page 210 (245)
Video
Video Not Decoding Error The decoder didn‟t receive a new video frame within 3
seconds.
Video Type Error- Selected video stream format is not supported by the decoder.
Video Unknown Error Video Decoder does not recognize the video stream.
Video Conversion Error- The video stream cannot be converted.
Invalid Output Format Error - The output format selected is invalid for the
combination of incoming stream and output card.
Incompatible Genlock Error - The Genlock Reference selected by the user is
incompatible with the incoming stream format.
Genlock Reference Error - The Genlock reference is set but there is no reference
signal detected.
SD Down-Conversion Error The conversion to an SD output format from HD
failed because the HD frame rate is not 29.97 (for NTSC) or 25 / 50 (for PAL).
4:2:2 Conversion Error Generated when chroma format is 4:2:2 and the native
resolution is 1080 and the output is 720, video scaling is not possible.
Video No Sync Error The video synchronization is not taking place due to the
large difference between the PTS and PCR (> 6 seconds).
Audio
DolbyE Not Decoding Error - The DolbyE PID has been set but is not being
decoded.
Audio (N) Not Decoding Error - Audio Decoder (N) didn‟t receive a new audio
frame within 3 seconds.
Audio (N) Unknown Error - Audio Decoder (N) does not recognize the audio
stream.
System
Fan Error - The fan is spinning at less than 500 RPM.
Temperature Error - The internal temperature has exceeded 70 Celsius.
DPI Stream Type Locked Error- User is not licensed to decode the selected
stream.
DPI
SCTE104 GPI Event- I2C failed to write to the splice request data to the decoder.
SCTE104 LAN Event- I2C failed to write to the splice request data to the decoder.
SCTE35 Event- Parsed transport stream and event was fired.
SCTE35 GPO Event- Relay configured by user to have an SCTE35 trigger and an
SCTE35 splice_insert message was received.
SCTE35 to SCTE104 Event- Although a number of things can trigger this event, one
example is: The decoder received an SCTE104 splice_request_data
message but failed to embedded it in the VANC because either an embedder
was not available or the ADP packet was too large for the number of
available lines.
SCTE35 Heartbeat Event- Have not received an SCTE35 message for a user
specified period of time (default 10min).