MRD 3187B - User Manual
Page 209 (245)
Appendix B – Error/Event List
General
Bitrate Error - The TS bitrate is not within 100 bps of 19.392 Mbps while using the
310M card, or it is greater than 160 Mbps while using ASI.
Tuner Lock Error – The FEC is not synchronized. Data on carrier is not
synchronized.
Video Unsupported Profile/Level - The video is not of a supported profile/level.
Carrier Lock Error - Cannot detect the carrier signal.
TS Rate Invalid - A burst of packets caused the receive FIFO to overflow.
Not Receiving Packets - The card is not receiving IP packets within 1 FEC period (1
second).
No TS Present Error - There is no sync byte (0x47) found in a 1 second period.
Transport Packet Error - There was an error in the transport stream.
Lock Error - A carrier cannot be found.
Low MER - The MER is lower than the threshold set by the user.
Low Level - The signal level is lower than the threshold set by the user.
System Time Event – If the unit is powered on/off, the time is manually updated, or
the time server is invalid, this event will be triggered.
CA Service Not Found- The CAM is configured to use selected PIDs, but the
selected PID is no longer available in the PMT.
Program Not Found – The Program / Service that is selected is not available.
Band Frequency Error – The Satellite Receiver tuning using Frequency and Offset
is not within the Receiver‟s tuning range.
FP Login Error Event – There was an attempt to unlock that front panel using the
wrong password.
All SDI Jacks Squelched Error –
Uncorrectable FEC Error Event – There was an FEC error that was uncorrectable.
Corrected FEC Error Event – There was an FEC error that was corrected.
Out of Order Packet Error Event – The IP connection has received an out of order
packet that is not able to be restored to its correct order.
Duplicate Packet Error – The IP connection has received a duplicate packet that
was disgarded.
Not Receiving IP Packets Error – An incoming IP connection is no longer receiving
any packets.
IP TS Sync Loss Error – An incoming IP connection has lost its TS synchronization,
it could still be receiving packets.
DMIP Failover Backup Error – The 8727 IP backup IP Receive Group is now being
used as the Active Receive Group.
DMIP Temperature Error – The 8727 has exceeded its normal operating
temperature limit.
Input Switched to Backup Error – The Backup input option has replaced the
Primary input option as the active input.
Line Conflict – An SDI output VANC line has a conflicting data trying to be placed
on the same line.
FEC Error Counter Rollover Event – The FEC error counter has restarted at 0.
FEC Error Counter Reset Event – There has been an FEC counter reset, setting all
of the FEC counters for the input option to 0.
AFD Code Not Present Event – The unit is configured to use or embed the AFD
code in the VANC, and the AFD code is not present with the input video.