MRD 3187B - User Manual
Page 209 (245)
Appendix B Error/Event List
General
Bitrate Error - The TS bitrate is not within 100 bps of 19.392 Mbps while using the
310M card, or it is greater than 160 Mbps while using ASI.
Tuner Lock Error The FEC is not synchronized. Data on carrier is not
synchronized.
Video Unsupported Profile/Level - The video is not of a supported profile/level.
Carrier Lock Error - Cannot detect the carrier signal.
TS Rate Invalid - A burst of packets caused the receive FIFO to overflow.
Not Receiving Packets - The card is not receiving IP packets within 1 FEC period (1
second).
No TS Present Error - There is no sync byte (0x47) found in a 1 second period.
Transport Packet Error - There was an error in the transport stream.
Lock Error - A carrier cannot be found.
Low MER - The MER is lower than the threshold set by the user.
Low Level - The signal level is lower than the threshold set by the user.
System Time Event If the unit is powered on/off, the time is manually updated, or
the time server is invalid, this event will be triggered.
CA Service Not Found- The CAM is configured to use selected PIDs, but the
selected PID is no longer available in the PMT.
Program Not Found The Program / Service that is selected is not available.
Band Frequency Error The Satellite Receiver tuning using Frequency and Offset
is not within the Receiver‟s tuning range.
FP Login Error Event There was an attempt to unlock that front panel using the
wrong password.
All SDI Jacks Squelched Error
Uncorrectable FEC Error Event There was an FEC error that was uncorrectable.
Corrected FEC Error Event There was an FEC error that was corrected.
Out of Order Packet Error Event The IP connection has received an out of order
packet that is not able to be restored to its correct order.
Duplicate Packet Error The IP connection has received a duplicate packet that
was disgarded.
Not Receiving IP Packets Error An incoming IP connection is no longer receiving
any packets.
IP TS Sync Loss Error An incoming IP connection has lost its TS synchronization,
it could still be receiving packets.
DMIP Failover Backup Error The 8727 IP backup IP Receive Group is now being
used as the Active Receive Group.
DMIP Temperature Error The 8727 has exceeded its normal operating
temperature limit.
Input Switched to Backup Error The Backup input option has replaced the
Primary input option as the active input.
Line Conflict An SDI output VANC line has a conflicting data trying to be placed
on the same line.
FEC Error Counter Rollover Event The FEC error counter has restarted at 0.
FEC Error Counter Reset Event There has been an FEC counter reset, setting all
of the FEC counters for the input option to 0.
AFD Code Not Present Event The unit is configured to use or embed the AFD
code in the VANC, and the AFD code is not present with the input video.