Specificat ions CDHD
22 User Manual
Sin g le Ph a se
1 2 0 / 2 4 0 VAC
Spe cifica t ion CD H D - 1 D5 CD H D - 0 0 3
Pow e r Te m pe r a t u r e
Fan
Norm ally operates at quart er power; when
temperature exceeds high-speed fan trigger
tem perature, operat es at full power
No Yes
Power Module Over-Temperature Fault Regulated
(° C)
80 ± 5% 80 ± 5%
Power Module Over-Temperatu re Fault
Non-regulated ( ° C)
100 ± 5% 100 ± 5%
Trigger Tem perature for High Speed Fan (° C) NA 45
Ex t e rnal Regene ra t ive
Resist or ( B1 + , B2 )
External regenerative
resistor requirement
(regen resist or not
supplied with drive)
Peak Current (A) 6.3 12.7
Minimum Resistance (Ω) 64 31.5
Power Rating (W)
Syst em -
dependent
Syst em -
dependent
Application Inform ation Internal Bus Capacitance (µF) 360 660
VLOW (Regen Circuit Turn Off) (VDC) 380 380
VMAX (Regen Circuit Turn On) (VDC) 400 400
Ta ble 3 - 2 . M e ch a n ical & Ele ctrical Spe cificat ions –
CDH D - 4 D5 / CD H D - 0 0 6 ( 1 2 0 / 2 4 0 VAC)
Single an d Th ree-
Ph a se 1 2 0/ 2 4 0 VAC
Spe cifica t ion CD H D - 4 D5 CD H D - 0 0 6
Ra tings
Input Power Circuit ( L1,
L2, L3)
Voltage (VAC Line- Line* ) Nominal ± 10% 120/ 240 120/ 240
Line Frequency (Hz) 50/ 60 50/ 60
120 VAC
1 Phase or
3 Phase
1 Phase or
3 Phase
240 VAC 1 Phase 1 Phase
Continuous Current (1/ 3 ph A rms) 8.5/ 4 10/ 5.8
Line Fuses (FRN-R, LPN, or equivalent) 10 10
Withstand Voltage ( Primary to Earth)
1500 VAC
(2121 VDC)
1500 VAC
(2121 VDC)
Control Circuit Input
Power (L1C, L2C )
120 ± 10 or 240 ± 10 VAC 1 Phase 1 Phase
Logic Input Fuse (Tim e
Delay)
120 or 240 VAC (A) 0.5 0.5
STO (Safe Torque Off) STO Power Supply (VDC) 24 ± 10% 24 ± 10%
STO Fuse (Tim e Delay) 120 or 240 VAC (A) 1.5 1.5