CDHD Diagnostics and Troubleshooting
User Manual 249
e 1 2 7 Digit a l Out put Over - Curren t Fa u lt
e127 Displayed in sequence
D e finit ion Digital Output Over-Current Detected
Type Fault
Act ive disa ble Yes
M e ssage # FLT 96
Descr iption Over-current detected on one of the digital outputs.
This fault disables the drive.
Action required
Verify correct wiring of the digital outputs. Make sure the
out put circuit is not short ed.
e 1 2 9 Fe edba ck Type Auto- De tect Fa ile d
e129 Displayed in sequence
D e finit ion Feedback type aut o-detection failed.
Type Fault
Act ive disa ble Not Applicable
M e ssage # FLT 106
Descr iption
Autom atic detection of feedback type on power-up failed
because neither sensAR nor HI PERFACE feedback device
was detected. Feedback device is either disconnected or
a different type.
This fault disables the drive.
Action required
Verify the connection. Manually configure the actual type
of feedback.