o9 Digit al Out put Over- Cur r ent Fa u lt
o9 Displayed in sequence
D e finit ion Digital out put over-current fault .
Type Fault
Act ive disa ble No
M e ssage # FLT 105
Descr iption Over-current at the digital output has been detected.
This fault disables the drive.
Action required Check the digital output connections.
P Over - Curr ent
P Flashing
D e finit ion Over-Current
Type Fault
Act ive disa ble No
M e ssage # FLT 3
Descr iption
Over-current at the drive output has been detected. This
fault disables the drive.
The drive allows this fault to occur up t o three tim es in
succession. When the fault occurs for the fourth tim e, t he
drive forces a delay of 1 m inut e before it can be
reenabled.
Action required
Check for a short circuit on the m ot or connect ion. Check
for excessive overshoot in the current loop.