Diagnostics and Troubleshooting CDHD
268 User Manual
P2 Unst able Curre nt Loop
P2 Displayed in sequence
D e finit ion Unstable Current Loop
Type Fault
Act ive disa ble No
M e ssage # FLT 100
Descr iption An unexpected high current overshoot has been det ected.
This fault disables the drive.
Action required Check and m odify current cont roller set tings.
P3 H igh I Q Current De tecte d
P3 Displayed in sequence
D e finit ion High IQ Current Detected
Type Fault
Act ive disa ble No
M e ssage # FLT 104
Descr iption The detected IQ current is greater t han 120% of ILIM.
This fault disables the drive.
Action required Check and m odify current controller set tings.