CDHD Diagnostics and Troubleshooting
User Manual 285
S1 Cannot Use SFBTYPE 1 w ith Analog OPMODE
S1 Displayed in sequence
D e finit ion Cannot Use SFBTYPE 1 with Analog OPMODE
Type Warning
Act ive disa ble Not Applicable
M e ssage # WRN 37
Descr iption
Cannot use the specified t ype of secondary feedback with
analog operation modes (i.e., OPMODE 1, OPMODE 3)
Action required
t Pow er St age Ove r- Te m pe r a tu r e
Control Board Ove r - Tem pe ra t ur e
I nt egrat ed Pow e r Module Over- Te m pe ra t u re
t Lit steadily
D e finit ion Power St age Over-Tem perature
Cont rol Board Over-Temperature
I ntegrat ed Power Module Over-Tem perature
Type Warning
Act ive disa ble Not Applicable
M e ssage # WRN 5
WRN 9
WRN 38
Descr iption
The t em peratur e on the power board and/ or on the
control board and/ or the power module ( I PM) has
exceeded the preset limit.
Action required
Check if t he am bient tem perature exceeds t he drive
specification. Otherwise contact Technical Support.