Chapter 12 Operating instructions
S3000
150 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009942/WK81/2012-11-28
Subject to change without notice
Technical specifications
Minimum Typical Maximum
Protective field supplement generally
necessary
100 mm
Supplement for retroreflectors in scan plane
at a distance of less than 1 m to the protective
field boundary
200 mm
Measurement error for measured data error
output up to 5.5 m and 1.8% remission
Systematic error ±5 mm
Statistical incl. systematic errors
at 1  ±24 mm
at 2  ±43 mm
at 3  ±62 mm
at 4  ±80 mm
at 5  ±99 mm
Evenness of the scan field at 5.5 m ±70 mm
Evenness of the scan field at 7 m ±88 mm
Distance from mirror axis of rotation (zero
point on the X and Y axis) to the rear of the
device
93 mm
Distance between centre of the scan plane
and the bottom edge of the housing
63 mm
Warning field range (radial) Approx.
20 m
33)
49 m
Distance measuring range 49 m
Number of multiple samplings (configurable
via CDS)
216
Power-up delay 9 s 20 s
Restart after (configurable) 2 s 60 s
Electrical data
Supply voltage (SELV)
34)35)
16.8 V 24 V 28.8 V
Permissible residual ripple
36)
±5 %
Switch on current
37)
2 A
Operating current without output load
38)
0.6 A 0.8 A
Operating current with max. output load,
without load due to incremental encoders
38)
2.2 A 2.3 A
33)
For objects with 20% reflectivity.
34)
Operation only in a short-circuit protected system with max. 8 A.
35)
To meet the requirements of the relevant product standards (e.g. EN 61 496<1), the external voltage supply
for the devices must be able to bridge a brief mains failure of 20 ms. Power supplies according to EN
60204<1 satisfy this requirement. Suitable power supplies are available as accessories from SICK.
36)
The absolute voltage level must not drop below the specified minimum voltage.
37)
The load currents for the input capacitors are not taken into account.
38)
With a typical supply voltage of 24 V.