Operating instructions Chapter 12
S3000
8009942/WK81/2012-11-28 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 151
Subject to change without notice
Technical specifications
Minimum Typical Maximum
Operating current with max. output load, with
max. load allowed due to incremental
encoders
38)
2.4 A 2.6 A
Power consumption without output load
38)
14 W 19 W
P
ower consumption with maximum output
load, without load due to incremental
encoders
38)
5
3 W55 W
Power consumption with maximum output
load, with max. load allowed due to
incremental encoders
38)
58 W 62 W
Power consumption in the stand-by mode or
park mode without output load
14 W 19 W
Electrical connection Plug-in connection housing with screw
terminal connections
Technical specifications, screw terminals
Cross-section of rigid cores 0.14 mm² 1.5 mm²
Cross-section of flexible cores
39)
0.14 mm² 1.0 mm²
American Wire Gauge (AWG) 26 16
Insulation stripping length for the cores 5 mm
Screw tightening torque 0.22 Nm 0.25 Nm
Cable length for power supply tolerance ±10%
For wire cross-section 1 mm² 50 m
For wire cross-section 0.5 mm² 25 m
For wire cross-section 0.25 mm² 12 m
Cable length for power supply tolerance ±5%
For wire cross-section 1 mm² 60 m
For wire cross-section 0.5 mm² 30 m
For wire cross-section 0.25 mm² 15 m
Cable length for power supply tolerance ±1%
For wire cross-section 1 mm² 70 m
For wire cross-section 0.5 mm² 35 m
For wire cross-section 0.25 mm² 17 m
Input for control switch for restarting or
resetting
Input resistance when HIGH 2 kb
Voltage for HIGH 11 V 24 V 28.8 V
Voltage for LOW –3 V 0 V 5 V
Input capacitance 15 nF
Static input current 6 mA 15 mA
Duration of actuation of the control switch 120 ms
39)
Core terminating sleeves are not required.