Maintenance
There is also a grease nipple in the lower part of the vibrating head, in the
position shown at Figure 70. For the greasing operations, follow the procedure
below:
A) Use the controls on the remote control to raise the vibrating head as
much as necessary to perform greasing.
B) Safely stop the machine. (*).
C) Completely unscrew the vent valve (3) with a 3 mm hexagonal wrench.
D) Pump in grease via the grease nipple (3) until it flows out of the vent.
E) After the grease has escaped, clean the vent and screw the valve (4)
back on.
ATTENTION
Use only hand grease and lithium grease for very high speed bearings.
Failure to comply with these instructions will result in irreparable damage to
the vibrating head apparatus.
4
3
(*) See par. “5.7” pag. 99
Figure 70