Supplementary system components and encoder system integration
8.1 Sensor Modules
AC Drive
346 Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Danger to life due to electric shock in the event of voltage flashovers at the temperature
sensor
Voltage flashovers in the signal electronics can occur in motors without safe electrical
separation of the temperature sensors.
• Use temperature sensors that fully comply with the specifications of the safety isolation.
• If safe electrical separation cannot be guaranteed (for linear motors or third-party
motors, for example), use a Sensor Module External (SME120 or SME125) or Terminal
Module TM120.
X524 Electronics power supply
Table 8- 3 X524: Electronics power supply
Voltage: 24 V (20.4 … 28.8 V)
Current consumption: max. 0.35 A
Max. current via jumper in connector:
20 A (15 A according to UL/CSA)
M Electronics ground
Type: Screw terminal 2 (Page 437)
Max. cross-section that can be connected: 2.5 mm²
The maximum cable length that can be connected is 10 m.
+" or "M" terminals are jumpered in the connector. This ensures that the supply
voltage is looped through.