EasyManua.ls Logo

Siemens simovert masterdrives

Siemens simovert masterdrives
1547 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function diagram
87654321
fp_mc_Y02_e.vsd
Terminal expansion EB1 No. 1
MASTERDRIVES MC
08.01.02
Analog outputs
-Y02 -
V2.5
Analog outputs
Smoothing
-1
-1
3
2
1
0
D
A
47
yx
Smoothing
-1
-1
3
2
1
0
D
A
48
yx
49
Uout = -10 V ... + 10 V
Uout = -10 V ... + 10 V
P666.2 *
% 100
x
[V]y =
P666.1 *
% 100
x
[V]y =
[V] Offset [V] ionNormalizat *
% 100
K5104
[V] Uout +=
[V] Offset [V] ionNormalizat *
% 100
K5105
[V] Uout +=
11 bit + sign
11 bit + sign
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
EB1
Viewed from the
front when
installed
U953.03 = ___
Time constant
0 ... 10000 ms
P665.1 (0)
P664.1 (0)
Offset
-200.00 ... +200.00 V
P667.1 (0.00)
Normalization
-200.00 ... +200.00 V
P666.1 (10.00)
K5104
r668.1
K
P663.1 (0)
Time constant
0 ... 10000 ms
P665.2 (0)
P664.2 (0)
Offset
-200.00 ... +200.00 V
P667.2 (0.00)
Normalization
-200.00 ... +200.00 V
P666.2 (10.00)
K5105
r668.2
K
P663.2 (0)

Table of Contents

Other manuals for Siemens simovert masterdrives

Related product manuals