Function diagram
87654321
fp_mc_Y02_e.vsd
Terminal expansion EB1 No. 1
MASTERDRIVES MC
08.01.02
Analog outputs
-Y02 -
V2.5
Analog outputs
Smoothing
-1
-1
3
2
1
0
D
A
47
yx
Smoothing
-1
-1
3
2
1
0
D
A
48
yx
49
Uout = -10 V ... + 10 V
Uout = -10 V ... + 10 V
P666.2 *
% 100
x
[V]y =
P666.1 *
% 100
x
[V]y =
[V] Offset [V] ionNormalizat *
% 100
K5104
[V] Uout +=
[V] Offset [V] ionNormalizat *
% 100
K5105
[V] Uout +=
11 bit + sign
11 bit + sign
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
EB1
Viewed from the
front when
installed
U953.03 = ___
Time constant
0 ... 10000 ms
P665.1 (0)
P664.1 (0)
Offset
-200.00 ... +200.00 V
P667.1 (0.00)
Normalization
-200.00 ... +200.00 V
P666.1 (10.00)
K5104
r668.1
K
P663.1 (0)
Time constant
0 ... 10000 ms
P665.2 (0)
P664.2 (0)
Offset
-200.00 ... +200.00 V
P667.2 (0.00)
Normalization
-200.00 ... +200.00 V
P666.2 (10.00)
K5105
r668.2
K
P663.2 (0)

Table of Contents

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals