Parameter
Description Data Read/write
P092
TrAdaption Gain
92
Gain of the equalizing controller of the rotor time constant
adaptation. With P92=0.00% the adaptation is switched
off.
Init: 0,00
Min: 0,00
Max: 200,00
Unit: %
Indices: -
Type: O2
Menus:
- Parameter menu
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
- Ready to switch on
r093
Tr Actual Value
93
Actual value of the rotor time constant Tr referred to P124. Dec.Plc.: 0
Unit: %
Indices: -
Type: O2
Menus:
- Parameter menu
- Drive setting
- Upread/free access
P094
TempPRE Tr
94
for future use Init: 0
Min: 0
Max: 65535
Unit: %
Indices: -
Type: O2
Menus:
- Parameter menu
- Upread/free access
Changeable in:
- Ready to switch on
P095*
Select Mot Type
95
Function parameter for selecting the connected motor.
0 = No motor connected
1 = Synchronous servomotor 1FK6/1FK7/1FT6/1FS6
2 = Induction servomotor 1PH7/1PL6/1PH4
3 = Synchronous servomotor general
4 = Induction motor general
5 = Torque motor 1FW3
If Siemens servomotors are used and 1, 2 or 5 are
entered, the connected motor can be directly selected in
P096, P097 or P099. The stored motor data are then
taken automatically from an internal list. If other motors
are used (entry of 3 or 4 ), the motor data must be entered
separately.
In the case of P095 = 3 or 4, automatic parameterization
(P115 = 1) should be called up after all the motor data
have been entered and before the start of automatic
motor identification.
The motor designation 1PA6 has been changed to 1PH7
(without changing the motor data).
Init: 1
Min: 0
Max: 5
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Motor data
- Quick parameterization
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P096*
Select1FK6/1FT6
96
Function parameter for selecting a
1FK6/1FK7/1FT6/1FS6 sychronnous servomotor from the
internal list of motors.
For parameter values, see annex of the "Compendium".
Note:
1FK7xxx are new 3-phase servo motors based on the
1FK6 series.
The data of 1FK7xxx HD (High Dynamic) and 1FK6xxx
therefore tally.
Init: 0
Min: 0
Max: 253
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Motor data
- Quick parameterization
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
P097*
Select 1PH7
97
Function parameter for selecting a 1PH7 (=1PA6), 1PL6
and 1PH4 induction motor from the internal list of motors.
For parameter values, see annex "Compendium".
Init: 0
Min: 0
Max: 253
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Motor/encoder
+ Motor data
- Quick parameterization
- Drive setting
- Upread/free access
Changeable in:
- Drive setting
11