Parameter
Description Data Read/write
U618*
X-SetV Tab
2618
Selection of the settable input value for the table (X-axis)
Function diagram [839.5]
Init: 823
Unit: -
Indices: -
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U619*
S.Set Tab
2619
The parameter selects the binector for setting the table to
the X-value defined via U618.
Function diagram [839.4]
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U620*
Table Width
2620
The parameter defines the width of the table in [LU]. The
table width is the maximum value of the X coordinate.
Index 1: for table 1
Index 2: for table 2
Index 3: for table 3
Index 4: for table 4
Index 5: for table 5
Index 6: for table 6
Index 7: for table 7
Index 8: for table 8
Changing this parameter sets the status of the associated
table to "untested"!
Function diagram [839.4]
index1: 4096
Min: 0
Max:
2147483647
Unit: -
Indices: 8
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U621*
S.Tab Sync
2621
Synchronizing table:
If the operating mode "scaling of Y-axis" (U614) is at 0,
this binector is not effective.
A jump at the output has to be expected for the "table"
operating mode.
If the operating mode "scaling of the Y-axis" (U614) is at
1, this binector is effective
0 = Scaling is adopted in the next axis cycle
1 = Scaling is adopted immediately
In function diagram [839.4]
Init: 0
Unit: -
Indices: -
Type: L2 ,B
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U622*
SetV Tab (X)
2622
Fixed setting value of X-axis for table. The setting
procedure is carried out via the binector selected by U619.
Function diagram [839.4]
Init: 0
Min: -
2147483648
Max:
2147483647
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U623*
FixScaleX-Axis
2623
Fixed values for scaling of the X-axis of the table.
Scaling of the X-axis means that the input value of the
table (x-axis) is multiplied by a factor. The factor is made
up of a numerator (U623.1) and a denominator (U623.2).
Scaling of the X-axis acts in the same way as a gearbox
connected ahead of a cam.
Function diagram [839.1]
index1: 1
Min: -32767
Max: 32767
Unit: -
Indices: 2
Type: I2
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
205