EasyManua.ls Logo

Siemens simovert masterdrives

Siemens simovert masterdrives
1547 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Description Data Read/write
U961*
Func Sequence 2
2961
Parameterizing of the processing sequence for functions
101 to 200.
index1: 1010
Min: 0
Max: 9999
Unit: -
Indices: 100
Type: O2
Menus:
- Parameter menu
+ Releases
- Upread/free access
Changeable in:
- Ready to switch on
U962*
Func Sequence 3
2962
Parameterizing of the processing sequence for functions
201 to 300.
index1: 2010
Min: 0
Max: 9999
Unit: -
Indices: 100
Type: O2
Menus:
- Parameter menu
+ Releases
- Upread/free access
Changeable in:
- Ready to switch on
U963*
Func Sequence 4
2963
Parameterizing of the processing sequence for functions
301 to 400.
index1: 3010
Min: 0
Max: 9999
Unit: -
Indices: 72
Type: O2
Menus:
- Parameter menu
+ Releases
- Upread/free access
Changeable in:
- Ready to switch on
n967
Function Seq 7
2967
Parameter for visualizing the processing sequence of the
internal functions with function numbers 701 ... 800
Dec.Plc.: 0
Unit: -
Indices: 100
Type: O2
Menus:
- Parameter menu
+ Releases
- Upread/free access
n968
Function Seq 8
2968
Parameter for visualizing the processing sequence of the
internal functions with function numbers 801 ... 900
Dec.Plc.: 0
Unit: -
Indices: 100
Type: O2
Menus:
- Parameter menu
+ Releases
- Upread/free access
n969
Function Seq 9
2969
Parameter for visualizing the processing sequence of the
internal functions with function number 901 .. 1000
Dec.Plc.: 0
Unit: -
Indices: 100
Type: O2
Menus:
- Parameter menu
+ Releases
- Upread/free access
U976*
FID
2976
Individual unit identification number, written during
production of the unit (cannot be changed!)
index1: 0
Unit: -
Indices: 2
Type: L2
Menus:
- Parameter menu
+ Releases
- Upread/free access
- Power section definition
Changeable in:
- Power section definition
U977*
PIN
2977
PIN = "Personal Identification Number". The special
functions (technology functions or PowerExtension
functions) of MASTERDRIVES MC are released by
entering the correct (unit-specific) individual PIN.
Index 1 and 2: Technology PIN
Index 3 and 4: PowerExtension PIN (firmware V2.2 and
higher)
index1: 0
Unit: -
Indices: 4
Type: L2
Menus:
- Parameter menu
+ Releases
+ Technology
+ Synchronism
+ Positioning
- Board configuration
- Upread/free access
- Power section definition
Changeable in:
- Power section definition
- Board configuration
- Ready to switch on
- Operation enabled
n978
Release
2978
Index 1: Release of the technology functions
0 => Technology blocked
1 => Technology released
2 => Technology released for 500h
Index 2: Release of the BigServo functions
0 => BigServo functions blocked
1 => BigServo functions released
Dec.Plc.: 0
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Releases
+ Technology
+ Synchronism
+ Positioning
- Board configuration
- Upread/free access
- Power section definition
254
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control

Table of Contents

Other manuals for Siemens simovert masterdrives

Related product manuals