EasyManuals Logo
Home>Siemens>DC Drives>simovert masterdrives

Siemens simovert masterdrives Compendium

Siemens simovert masterdrives
1547 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #175 background imageLoading...
Page #175 background image
Parameterizing Steps 08.2012
6SE7087-6QX70 (Version AN) Siemens AG
6-10 Compendium Motion Control SIMOVERT MASTERDRIVES
Order number In [A] PWE
6SE7035-1EK70 -1AA0
or -1AA1
510
1)
423
2) 3)
233
6SE7036-0EK70 -1AA0
or -1AA1
590
1)
491
2) 3)
237
6SE7037-0EK70 -1AA0
oder -1AA1
690.0
4)
168
Order number In [A] PWE
6SE7035-1TJ70 -1AA1
or -1AA0
510.0
1)
423
2) 3)
206
6SE7036-0TJ70 -1AA1
or -1AA0
590.0
1)
491
2) 3)
209
6SE7037-0TJ70 -1AA0
or -1AA1
690.0
4)
167
6SE7041-3TL70 -1AA0
or -1AA1
1300.0
4)
199
6SE7038-6TK70 -1AA0
or -1AA1
860.0
4)
213
6SE7041-1TK70 -1AA0
or -1AA1
1100.0
4)
221
1)
theoretical rated output current at 3 kHz pulse frequency; rated output
current can only be achieved if the Power Extension PIN is entered.
2)
rated output current at 5 kHz pulse frequency; the permissible rated output
current will be reduced further at higher pulse frequencies (see technical
data, derating)
3)
This device is a chassis unit (from type J). The overload over 30 s is
therefore limited to 1.36 x the rated output current at 5 kHz.
4)
This unit is a so-called chassis unit and can only be operated up to a
maximum pulse frequency of 2.7 kHz. The overload for 30 s is limited to
1.36 times the rated output current.
Water-cooled AC-AC
frequency converter
Water-cooled DC-AC
inverter

Table of Contents

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals