08.2012 Parameterizing Steps
Siemens AG 6SE7087-6QX70 (Version AN)
SIMOVERT MASTERDRIVES Compendium Motion Control 6-39
Note: The "Raise MOP" and "Lower MOP" keys are only effective
if the operating display (r000) is selected.
M24
1 = Operation
0 = Fault
1 = Raise MOP
Acknowledge
OFF1
1 = Lower MOP
MOP Accel Time
P431
MOP Decel Time
P432
Conf MOP
P425
MOP(max)
P421
MOP(min)
P422
00x0= ... Without storing after OFF
00x1= ... Storing after OFF
-X101/2
-X101/3
-X101/4
Setpoint and command source
PMU
(not for Compact PLUS units)
X300