09.2008 Functions
Siemens AG 6SE7087-6QX70 (Version AK)
SIMOVERT MASTERDRIVES Compendium Motion Control 7-45
If the deviation is within the innermost window (window 1), the homing
point is not set. Neither is the homing point set if the deviation is outside
the outermost window (window 2).
The output B0892 error homing point proximity switch outside window 2
is activated.
This output signal stays on until a homing point mark is next evaluated.
Both windows can be disabled individually by assigning them values of
0.
Fault and warning messages
The free BASIC POSITIONER blocks do not generate any fault or
warning messages. The positioning software does not respond to
messages caused by incorrect parameters either (e.g. violation of
limit values).
Definitions
Def. homing:
Homing on the fly, also referred to as post-homing, appears in the
correction value/homing block, function diagram 789c, with window
evaluation.
Homing as homing movement mode with reversing cam appears in
the setting value/setpoint block function diagram 789a.

Table of Contents

Other manuals for Siemens simovert masterdrives

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens simovert masterdrives and is the answer not in the manual?

Siemens simovert masterdrives Specifications

General IconGeneral
BrandSiemens
Modelsimovert masterdrives
CategoryDC Drives
LanguageEnglish

Related product manuals