09.2008 Functions
Siemens AG 6SE7087-6QX70 (Version AK)
SIMOVERT MASTERDRIVES Compendium Motion Control 7-63
Band-stop filter of average quality and semi-suppression of the
resonant frequency
(P256 = 1; P254 = 50 Hz; P253 = 1.0; P257 = 50 %)
1 10 100
1
.
10
3
-6
-4.5
-3
-1.5
0
1.5
3
Frequency in Hz (no omega!)
3
-6
Ampl
fmaxfmin
Frequency
-90
-67.5
-45
-22.5
0
22.5
45
67.5
90
90
Phase
1 10 100
1
.
10
3
Frequency in Hz (no omega!)
fmaxfmin
Frequency
-90
Example 2