Communication / PROFIBUS 09.2008
6SE7087-6QX70 (Version AK) Siemens AG
8.2-74 Compendium Motion Control SIMOVERT MASTERDRIVES
So-called identification bytes are transferred in the configuration telegram
of the PROFIBUS-DP master. These bytes determine the type of PPO for
the useful-data telegram.
These bytes can be assigned different values for selecting a particular
type of PPO (except for PPO type 1). For PPO type 4, for example, either
identification byte 0 = 245 and identification byte 1 = 0 can be entered or
only identification byte 0 = 245. If an unknown combination of
identification bytes is received, the CBP sets the bit "parameterization
error" in the diagnostic telegram to the PROFIBUS-DP master.
PPO Identification byte
0
Identification byte
1
Identification byte
2
Identification byte
3
COMET200
type Dec Hex COM Dec Hex COM Dec Hex COM Dec Hex COM Version
1 243 F3 4AX 241 F1 2AX V4.x/V5.x
2 243 F3 4AX 243 F3 4AX 241 F1 2AX 0 0 0 V4.x/V5.x
2 243 F3 4AX 243 F3 4AX 241 F1 2AX V4.x/V5.x
2 243 F3 4AX 245 F5 6AX V5.x
3 241 F1 2AX 0 0 0 V4.x/V5.x
3 0 0 0 241 F1 2AX V4.x/V5.x
3 241 F1 2AX V4.x/V5.x
4 0 0 0 243 F3 4AX 241 F1 2AX 0 0 0 V4.x/V5.x
4 0 0 0 243 F3 4AX 241 F1 2AX V4.x/V5.x
4 0 0 0 243 F5 6AX V5.x
4 245 F5 6AX 0 0 0 V5.x
4 245 F5 6AX V5.x
5 243 F3 4AX 243 F3 4AX 243 F3 4AX 241 F1 2AX V4.x/V5.x
5 243 F3 4AX 243 F3 4AX 241 F1 2AX 243 F3 4AX V4.x/V5.x
5 243 F3 4AX 249 F9
10A
X
V5.x
Table 8.2-14 Values for the identification bytes
Selecting the type of
PPO