Commissioning
4.5 Establishing an online connection to the drive unit
Commissioning with Startdrive
144 Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Procedure
To assign an IP address, proceed as follows:
1. Double-click "Online & Diagnostics" under "Online access" in the project navigator.
2. Double-click the "Functions" entry in the secondary navigation of the working area.
3. Double-click the "Assign IP address" entry.
Figure 4-49 Assigning an IP address
4. Enter an IP address that matches your project.
5. Enter an appropriate subnet mask.
6. Click on "Assign IP address"
7. Update the display at "Online access". The IP address is now displayed.
The MAC address is read out automatically.
Result
The IP address has been assigned to the drive.