Diagnostics
5.3 Diagnostics via Startdrive
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
349
Result
The configuration is transferred as new trace configuration into the "Traces" system folder.
A trace configuration with the same name in the system folder is overwritten.
5.3.2.10
Deleting a trace configuration
Requirement
An online connection has been established to the drive.
A trace is saved in the drive.
Procedure
Proceed as follows to delete a trace configuration in the drive:
1. Open a trace configuration in the drive (see Chapter "Creating or calling a trace
(Page 339)").
2. If required, activate the icon
for monitoring.
3. Click on icon
to delete the selected trace configuration.
A confirmation prompt opens.
4. To confirm the deletion, in the query, click on "Yes".
Or
1. In the project navigation, select one or several trace configurations in the drive
/ .
2. Call the "Delete" shortcut menu to delete the trace configurations in the drive.
A confirmation prompt opens.
3. To confirm the deletion, in the query, click on "Yes".