Commissioning
4.10 Safety Integrated commissioning
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
265
Transmission via PROFIsafe
Once SLA has been parameterized and selected, the monitoring results are transmitted in
status words S_ZSW1.8 or S_ZSW2.8.
Note
Response to bus failure
If p9580
0 and SLA is active, in the event of a communication failure, the parameterized
ESR reaction only occurs if a STOP with delayed pulse suppression when the bus fails has
been parameterized as the SLA response (p9579
10).
Transmission via SIC
Once "SLA" has been parameterized and selected, the monitoring results are also
transmitted in SIC in status word S_ZSW1B.8 (see Chapter "Communication via SIC/SCC
(Page 251)"). You will find this status word in telegrams 700 and 701.
4.10.4.13
Function diagrams and parameters
Function diagrams (see SINAMICS S120/S150 List Manual)
2814
SI Basic Functions
- SBC (Safe Brake Control), SBA (Safe Brake Adapter)
2819
SI
Extended Functions - SS1, SS2, SOS, internal STOP B, C, D, F
2820
SI Extended Functions
- SLS (Safely-Limited Speed)
2821
SI Extended Functions
- Safe homing
2823
SI Extended Functions
- SSM (Safe Speed Monitor)
2824
SI Extended Functions
- SDI (Safe Direction)
2825
SI Extended Functions
- SAM (Safe Acceleration Monitor), SBR (Safe Brake
Ramp)
2836
SI Extended Functions
- SBT (Safe Brake Test)
2838
SI Extended Functions
- SLA (Safely-Limited Acceleration)