Diagnostics 
  5.2 Diagnostics using LEDs 
Commissioning with Startdrive 
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1 
321 
 
Additional modules 
5.2.3.1
 
Table 5- 20  Control Supply Module – description of the LEDs 
READY  –  off  Electronic power supply is missing or outside permissible 
– 
Green  Continuous 
light 
Component is ready to operate.  – 
DC LINK  –  off  Electronic power supply is missing or outside permissible 
– 
Orange  Continuous 
DC link voltage within permissible tolerance range.  – 
Red  Continuous 
DC link voltage outside permissible tolerance range.  – 
 
SMC10/SMC20 Sensor Module Cabinet 
Table 5- 21  Sensor Module Cabinet 10/20 (SMC10/SMC20) – description of the LEDs  
RDY 
READY 
–  off  Electronic power supply is missing or outside permissible 
– 
Green  Continuous 
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place. 
– 
Orange  Continuous 
DRIVE-CLiQ communication is being established.  – 
Red  Continuous 
light 
At least one fault is present in this component. 
 
LED is controlled irrespective of the corresponding mes-
sages being reconfigured. 
Remedy and 
acknowledge fault 
Green/red  Flashing 
Firmware is being downloaded.  – 
Flashing 
light 2 Hz 
Firmware download is complete. Wait for POWER ON  Carry out a POWER 
ON 
Green/ 
orange 
or 
Red/ 
Flashing 
light 
Component recognition via LED is activated (p0144). 
 
Both options depend on the LED status when module 
recognition is activated via p0144 = 1. 
–