EasyManua.ls Logo

Siemens SINAMICS S120 - Additional Modules; Control Supply Module; SMC10;SMC20 Sensor Module Cabinet

Siemens SINAMICS S120
438 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Diagnostics
5.2 Diagnostics using LEDs
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
321
5.2.3
Additional modules
5.2.3.1
Control Supply Module
Table 5- 20 Control Supply Module description of the LEDs
LED
Color
State
Description, cause
Remedy
READY off Electronic power supply is missing or outside permissible
tolerance range.
Green Continuous
light
Component is ready to operate.
DC LINK off Electronic power supply is missing or outside permissible
tolerance range.
Orange Continuous
light
DC link voltage within permissible tolerance range.
Red Continuous
light
DC link voltage outside permissible tolerance range.
5.2.3.2
SMC10/SMC20 Sensor Module Cabinet
Table 5- 21 Sensor Module Cabinet 10/20 (SMC10/SMC20) description of the LEDs
LED
Color
State
Description, cause
Remedy
RDY
READY
off Electronic power supply is missing or outside permissible
tolerance range.
Green Continuous
light
The component is ready for operation and cyclic DRIVE-
CLiQ communication is taking place.
Orange Continuous
light
DRIVE-CLiQ communication is being established.
Red Continuous
light
At least one fault is present in this component.
Note:
LED is controlled irrespective of the corresponding mes-
sages being reconfigured.
Remedy and
acknowledge fault
Green/red Flashing
light 0.5 Hz
Firmware is being downloaded.
Flashing
light 2 Hz
Firmware download is complete. Wait for POWER ON Carry out a POWER
ON
Green/
orange
or
Red/
orange
Flashing
light
Component recognition via LED is activated (p0144).
Note:
Both options depend on the LED status when module
recognition is activated via p0144 = 1.