Diagnostics
5.2 Diagnostics using LEDs
Commissioning with Startdrive
326 Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
5.2.3.6
Voltage Sensing Module VSM10
Table 5- 27 Meanings of the LEDs on the Voltage Sensing Module VSM10
LED
Color
Status
Description, cause
Remedy
READY Off The electronics power supply is missing or outside the
permissible tolerance range.
Green Continuous
light
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
Orange Continuous
light
DRIVE-CLiQ communication is being established.
Red Continuous
light
This component has at least one fault.
Note:
LED is controlled irrespective of the corresponding mes-
sages being reconfigured.
Remove and
acknowledge the fault.
Green/red Flashing
light 0.5 Hz
Firmware is being downloaded.
Flashing
light 2 Hz
Firmware download is complete. The system waits for
POWER ON.
Carry out a POWER
ON.
Green/
orange
or
Red/
orange
Flashing
light
Detection of the component via LED is activated (p0144 =
1).
Note:
Both options depend on the LED status when component
recognition is activated.
5.2.4
Terminal Modules
5.2.4.1
Terminal Module TM15
Table 5- 28 Meanings of the LEDs on the Terminal Module TM15
LED
Color
Status
Description, cause
Remedy
READY - Off The electronics power supply is missing or outside the per-
missible tolerance range.
Green Continuous
light
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
Orange Continuous
light
DRIVE-CLiQ communication is being established.
Red Continuous
light
This component has at least one fault.
Note:
The LED is activated irrespective of whether the correspond-
ing messages have been reconfigured.
Correct and
acknowledge the
fault.
Green/
red
Flashing
light 0.5 Hz
Firmware is being downloaded.
Flashing
light 2 Hz
Firmware download is complete. The system waits for
POWER ON.
Carry out a POWER
ON.