Diagnostics
5.3 Diagnostics via Startdrive
Commissioning with Startdrive
340 Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
Displaying a saved trace configuration or an appropriate curve diagram
Proceed as follows to display a saved trace configuration:
1. In the project navigation, double-click on the appropriate icon (
offline/ online) the
trace configuration, a trace in the drive or a measurement.
The "Configuration" or "Diagram" tab is opened in the working area.
Figure 5-5 Calling the trace dialog
2. If necessary, click on the "Configuration" tab to display it.
- or -
3. If, instead of the trace configuration, you wish to display the curve diagram, then click on
the "Diagram" tab.
5.3.2.3
Configuring a trace
With a double-click an (empty) trace configuration is created and selected in the project
navigation. Configuring the trace comprises 2 subareas:
Selecting and configuring signals
Configuring recording conditions
Note
Durability of trace data
The trace configuration is persistently saved. The data is kept even when switching off and
switching on.
Trace signals that have been recorded are not automatically saved, and are therefore lost
when the system is switched off. As a consequence, trace recordings can be manually saved
in the project (see Chapter "
Saving measurements in the project (Page 347)") - or exported
in a file structure (see
Chapter "Exporting and importing measurements (Page 348)").