Diagnostics
5.3 Diagnostics via Startdrive
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
341
Selecting and configuring signals
Proceed as follows to configure signals that are to be recorded:
1. Click on the first empty cell in the "Name" column.
Figure 5-6 Configuring trace signals
2. Select a signal. The following options are available:
In the "Name" column, click on the icon
and select a parameter.
Enter the parameter name in the "Name" column - or part of the name in the cell. The
field shows the possible parameters in the drop-down list.
The "Address" column shows the parameter number. A color is recommended in the
"Color" column.
To see the selection of parameters from all drive objects of the drive unit, put an
asterisk and a period - "*." - in front of the search term, e.g. "*.r0063".
3. If you wish to assign another color to the signal, from the drop-down list select another
color in the "Color" column.
4. Click in the "Comment" column and enter a comment for the signal.
5. Repeat the procedure from step 1 until all of the signals to be recorded have been
entered into the table.
You can configure a maximum of 8 signals for each trace.