Commissioning
4.7 Basic parameterization of the drive objects
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
165
Setting or changing web server user accounts
For SINAMICS S120, the rights of both user accounts "SINAMICS" and "Administrator" are
permanently defined and cannot be changed by users.
The user "Administrator" has full rights by default. However, the standard "SINAMICS" user
only has restricted access rights.
You can make the following settings in Startdrive for the web server user accounts:
Enable or disable user "SINAMICS" or user "Administrator"
Set a password for user "SINAMICS" or user "Administrator"
Change the password of user "SINAMICS" or user "Administrator"
Delete the password of user "SINAMICS"
Default password settings after first commissioning
SINAMICS: No password set
It is recommended that you assign a password. This must comprise at least 8 characters.
Administrator: No password set
A password must be assigned for this user. This must comprise at least 8 characters.
Note
Secure passwords
The password must include the following elements to provide protection against
unauthorized access, e.g. unauthorized persons.
At least 8 characters
Uppercase as well as also lowercase letters
Numbers and special characters (e.g.: ?!%+ ...)
The password must not be used elsewhere.
Enabling users
The "SINAMICS" user and the "Administrator" user can be enabled with their own specific
rights. You can also set whether password protection will be active for the "SINAMICS" user.
To enable a user and activate a password, proceed as follows:
1. Activate the "Enable SINAMICS user" option.
And/Or
2. Activate the "Enable administrator user" option.