Commissioning
4.7 Basic parameterization of the drive objects
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
173
Define the offset (p0783)
The offset is applied additively to the signal to be output. The signal to be output can thus be
displayed within the measuring range.
1. Enter the required offset value in the "Offset" field for the relevant measuring socket.
Function diagrams (see SINAMICS S120/S150 List Manual)
8134
- measuring sockets (T0, T1, T2)
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p0771[0...2]
CI: Measuring sockets signal source
p0777[0...2]
aracteristic curve value x1
p0778[0...2]
Measuring sockets characteristic curve value y1
p0779[0...2]
Measuring sockets characteristic curve value x2
p0780[0...2]
Measuring sockets characteristic curve value y2
p0783[0...2]
p0784[0...2]
Measuring sockets limitation on/off
r0772[0...2]
Measuring sockets signal to be output
r0774[0...2]
Measuring sockets output voltage
r0786[0...2]
Measuring sockets scaling per volt