Startdrive commissioning tool
2.5 User interface - trace function
Commissioning with Startdrive
Commissioning Manual, 11/2017, 6SL3097-4AA10-0BP1
49
"Formula" Display or entry of a formula
A formula can contain mathematical functions with numbers and signals. Use the formula editor to
conveniently create formulas.
Call of the formula editor for calculated signals
Click on the icon to open the formula editor.
Display and setting option for the color of the signal
"Signal group" Display or input of the signal group name for one signal group
The Y-scales are scaled identically for all signals of one signal group.
Enter an identical signal group name for those signals that are to be scaled identically.
Signals can be removed from the signal group by deleting the signal group name.
The signal groups can be saved via the function "Use current view as standard" (icon ).
Binary signals cannot be grouped.
In hex display format, group only the signals with a format compatible to the sign for the display.
Gray field for
chain icon
Move the cursor over the gray field or the chain icon ( or ) to add the signal to a signal group
or delete the signal from the signal group.
Clicking the
chain icon adds the signal to a signal group or creates a new signal group.
Clicking the
chain icon removes the signal from the signal group.
For a selected signal with signal group, the chain icon displays all signals of the same signal
Input field The input field displays the signal group name.
As an alternative to the chain icon, you can assign or delete a group name via text input in this
Display or input of the minimum value for the scaling of the signal
Display or input of the maximum value for the scaling of the signal
Display of the value at the position of the first measurement cursor
"Y(t2)" Display of the value at the position of the second measurement cursor
Display of the value difference between the first and the second measurement cursor
"Unit" Display of the unit (e.g. for used-based values from technology objects)
Display and input option for a comment about the signal