Motor Modules Booksize
4.3 Motor Module with external air cooling
Booksize power units
Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
369
External air cooling 6SL3121- 2TE13-0AAx 2TE15-0AAx 2TE21-0AAx 2TE21-8AAx
Rated current A 2x3 2x5 2x9 2x18
Output voltage V
ACrms
0 -480
Overvoltage tripping
Undervoltage tripping
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics current consumption at 24 V A
DC
1.0 1.0 1.0 1.0
Total power loss
(including electronic losses)
1)
W 95 129 184 344
Rated output current (I
n
) A 2x3 2x5 2x9 2x18
Base load current (I
base
) A 2x2.6 2x4.3 2x7.7 2x15.3
Intermittent duty current (l
S6
) 40 % A
ACrms
2x3.5 2x6 2x10 2x24
Peak current (l
max
) A
ACrms
2x6 2x10 2x18 2x36
DC link busbar current carrying capacity A 100 100 100 100
24 V busbar current carrying capacity A 20 20 20 20
Rated power (600 V, 4 kHz) kW 1.6 2.7 4.8 9.7
Max. pulse frequency without derating kHz 4 4 4 4
Max. pulse frequency with derating kHz 16 16 16 16
Max. ambient temperature without derating °C 40 40 40 40
Max. ambient temperature with derating °C 55 55 55 55
DC link capacitance μF 110 220 220 705
Sound pressure level dBA <60 <60 <60 <60
Cooling air requirement m
3
/h 29.6 29.6 29.6 56
Weight kg 5.8 5.8 5.7 8.6
1)
For an overview, see the power loss tables in chapter Cabinet Design