98 Manual, (GH2), 06/2008, 6SL3097-2AC00-0BP6
Table 2-29 Replacing the fan in an Active Interface Module, 80 kW, 120 kW
Open the fan cover. Unscrew the
combination screws M5/3 Nm
Open the fan cover Remove the connector
Unscrew the screws M3/1.8 Nm Release the connection cables Remove the fan
To install, carry out the above steps in reverse order. The torques must be carefully