6.8.2.7 Connection examples with SIMATIC S7-1200
Overview
This section shows the examples of connection between S200 PTI and SIMATIC S7-1200. The
signal assignment shown in the examples is based on default settings. You can assign dierent
signals to inputs and outputs based on your needs.
Connection example
Fast pulse train input position control mode (Fast PTI)
The following illustration uses high-speed 5 V dierential pulse train inputs and outputs as an
example.
Connecting
6.8Connecting the inputs and outputs
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 157