EasyManua.ls Logo

Siemens SINAMICS S200 - Connecting the Service Interface (Ethernet); Interface Description - X127

Siemens SINAMICS S200
764 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.10 Connecting the service interface (Ethernet)
6.10.1 Interface descr
iption - X127
Overview
The converter connects to a commissioning device via the Ethernet interface X127. The
interface o󹪜ers 24VDC power supply to the connected device. The transmission rate on the
interface is 10Mbit/s or 100Mbit/s.
Requirement
Note
The ser
vice interface X127 is used for commis
sioning and diagnostics. Do not use it for long-
term monitoring.
Description
Table 6-13 Interface X127
X127 Pin
Designation Technical speci󹪝cations
RJ45 socket
1 TXP Transmit data +
2 TXN Transmit data -
3 RXP Receive data +
4 P24_POE Power supply over Ethernet, 24VDC
5 P24_POE Power supply over Ethernet, 24VDC
6 RXN Receive data -
7 M_POE Power supply over Ethernet, reference ground
8 M_POE Power supply over Ethernet, reference ground
LED states
For diagnostic purposes,
the service interface X127 is equipped with a green LED and a yellow
LED.
Table 6-14 LED states of the service interface X127
LED Color Status Description
Link port - O󹪜 Missing or faulty link
Green Continuous light 10 or 100 Mbit link is available
Activity port - O󹪜 No activity
Yellow Flashing light Sending or receiving data
Connecting
6.10Connecting the service interface (Ethernet)
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 163