4)
To comply
with permissible line harmonics, depending on the line connection conditions, di󹪜erent values may be required.
5)
The maximum permissible short-circuit current for 200 V variants with Type E Combination Motor Controllers is 65 kA.
6)
When the converter works with a motor with a brake, the voltage tolerance of 24 V DC power supply must be -5% to +20%
to meet the voltage requirement of the brake.
13.1.3 Speci󹪝c data of the 200 V converters
Technical data
Table 13-3 Speci󹪝c technical data of 200 V converters frame size A
Article No. 6SL5☐10-1BB 10-1AA0 10-2AA0
Frame size FSA FSA
Rated input current (A) 1 AC 1.2 2.0
3 AC 0.6 1.1
Rated output current (A) 0.81 1.33
Maximum output current (A) 3.3 5.1
Maximum supported motor power (kW) 0.1 0.2
Power loss (W) 12 15
Inrush current (A) 10.5 10.5
Fuse according to IEC 3NA3804 (4 A) 3NA3804 (4 A)
3NW6304-1 (4 A) 3NW6304-1 (4 A)
Fuse according to UL, ClassJ 3 A 3 A
Leakage current (mA) 1 AC 19 19
3 AC 24 24
Outline dimensions (W x H x D, mm) 40 x 170 x 135 40 x 170 x 135
Weight (g) S200 PTI 763 809.6
S200 Basic PTI 763 763
Table 13-4 Speci󹪝c technical data of 200 V conv
erters frame size B
Article No. 6SL5☐10-1BB 10-4AA0
Frame size FSB
Rated input current (A) 1 AC 3.0
3 AC 1.8
Rated output current (A) 2.4
Maximum output current (A) 9.2
Maximum supported motor power (kW) 0.4
Power loss (W) 24
Inrush current (A) 8.5
Technical data
13.1Technical data of the converter
SINAMICS S200 pulse train servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646767B AA 507